Define the purchasing requirement
Dissolved-air flotation requires a different acceptance record from simple settling. A PAM candidate should be judged with the actual coagulation and air-contact route, not selected only because it makes a heavy floc in a beaker. Identify potable or industrial use before reviewing samples.
State the treated-water destination and the actual measurement used for acceptance. Keep untested water conditions outside the initial approval rather than extending a sample result to every future operating state.
Describe the flotation duty
Record water source, solids character, coagulant, pH, mixing and recycle-air arrangement. Include float handling and current limitations such as fines carryover, unstable surface solids or excess chemical consumption.
The ionic selection guide supports a sample bracket but does not determine air attachment from a family name.
Use flotation-relevant comparison
Keep sample preparation and active additions traceable, then evaluate leading conditions in a suitable flotation test or controlled plant trial. Record clarified water, float behavior and skimming at consistent times.
A settling jar can screen coagulation response but cannot alone reproduce bubble contact, recycle conditions or flotation removal.
Keep approval and operation linked
Document the useful dose window, injection point and preparation method. Include downstream filter response where present and verify exact-product approval for potable applications.
Separate chemistry from mechanical air-delivery or skimmer problems. A polymer purchase should not be represented as a guaranteed correction for an unverified equipment fault.
Resolve the limiting condition
A candidate that gives a clearer settled jar but a fragile float layer has not demonstrated a DAF improvement. Compare the actual floated-water and solids-removal requirements before award.
Keep the incumbent or untreated reference in the comparison and record measurement timing. A repeat trial is preferable to a confident product ranking when observed differences are within sampling or instrument variability.
Record the release conditions
| Purchase check | Required evidence | Approval boundary |
|---|---|---|
| Process | Coagulation and air-contact record | Actual route represented |
| Test | Float and clarified-water evidence | Not settling alone |
| Release | Useful dose and product identity | Controlled recurring use |
Connect the accepted sample, commercial product code, preparation method and operating window. Preserve both failed and acceptable conditions so purchasing can distinguish a bounded recommendation from an unrestricted performance claim.
Request a focused proposal
Send DAF layout and operating data, source-water conditions, current chemistry and float-removal targets. Request a limited coded trial set with the required flotation confirmation clearly stated.
Send the water-treatment PAM sample and quotation request and review quality and delivery requirements with Gongyi Xinqi Polymer Co., Ltd.. Confirm the offered grade and documentation before placing an order.

